Why Door Access Planning Matters Early in Commercial Renovations

The Short Version for Owners and Project Teams

  • Early Format Decisions: Choosing the credential format during design keeps readers, door hardware, and replacement cards aligned from day one.
  • Existing Card Programs: Many renovations can keep the 125 kHz proximity cards occupants already carry and add smart card capability in stages.
  • Code-Ready Reader Placement: ADA reach ranges, NFPA 101 egress rules, and the door frame determine how each reader is mounted.
  • Controlled Construction Access: Contractor credentials issued from their own number block and set to expire at completion keep secured areas protected.
  • Complete Closeout Records: Documenting the card format, facility code and issued number range lets the owner reorder matching cards at any time.

A commercial renovation brings many building systems back online at once, and door access is one of the few that every occupant uses on the first morning. Even so, proximity cards, key fobs, and smart cards are often treated as a final operations detail and ordered once the finishes are in. In practice, the credential format influences which readers the security consultant can specify, how the access control panel is programmed, and which cards the owner will rely on for years after the building reopens.

As an experienced Canadian ID card and access credential specialist, Avon Security Products works with property managers, facility teams and integrators planning access cards for renovated buildings. Settling the credential format during design, alongside the door hardware and low-voltage cabling, gives every trade the same standard to build to and keeps opening week focused on occupants rather than card orders.

Why the Existing Card System Should Guide the Design

Most renovations take place in occupied buildings, where staff and tenants already carry working credentials. Understanding those cards is the starting point for every reader decision. Many commercial buildings still run 125 kHz proximity cards, which store a number in a set data format such as the open 26-bit H10301 format.

That number combines an 8-bit facility code that identifies the site with a 16-bit card number that identifies the individual card, and a new card only works when all of those values match what the system expects. When the original records are missing, the format and facility code are often printed on the label of a previous card box or stored in the card format settings of the access control panel.

Proximity cards are inexpensive and simple to administer. However, they send the same number every time they are read, and that number can be copied with inexpensive equipment. For that reason, federal guidance such as NIST SP 800-116 directs government sites toward credentials that authenticate cryptographically.

The depth of the renovation usually determines the right path. For a light refresh that keeps the existing readers and panels, the owner can continue with the current cards and add more of the same. Facility teams in that position can source Avon Security Products proximity cards and key fobs programmed to the building’s existing format and facility code, so occupants keep the credentials they already carry.

A deeper renovation can add multi-technology readers that accept both 125 kHz and 13.56 MHz smart cards. Dual-technology cards, which carry a proximity chip and a smart chip in one card, then allow each person to use a single credential on old and new doors during a phased migration. A full replacement is typically reserved for gut renovations or change-of-use projects, where the access control system is being rebuilt.

How Specifications and Codes Shape Reader Placement

Once the credential decision is made, it needs to reach the drawings in a form every trade can follow. Readers, controllers, and credentials are usually specified under electronic access control in Division 28 of CSI MasterFormat, while the locks and exit devices on the same doors fall under Division 08 door hardware. Stating the card format in the security specification and repeating it in the hardware schedule keeps the electrical contractor and integrator working from the same information.

Accessibility requirements then guide the mounting position. In the US, card readers are operable parts under section 309 of the 2010 ADA Standards for Accessible Design, which places them within the reach ranges in section 308. For an unobstructed forward or side reach, that means 15 to 48 inches above the floor. The door frame matters as well. Narrow aluminum storefront frames, common in retail and hospitality renovations, call for slim mullion-mount readers, and readers installed directly on metal can lose read range without the manufacturer’s spacer.

On the egress side, the NFPA 101 Life Safety Code sets the conditions under which access-controlled doors must release, including when the lock loses power, and local building and fire codes may add further requirements. Canadian locations follow the provincial building code and, where it is referenced, CSA B651 for accessibility.

Managing Credentials Through Every Construction Phase

Phased renovations often have trades, early tenants, and existing occupants sharing the same building, each needing access at a different time. Contractor fobs issued from their own block of card numbers and set to expire at substantial completion give the general contractor-controlled access to secured areas. They are also easy to spot in the access control software and can be deactivated together when work ends.

Where trades also need visible site identification, printable proximity cards can carry a photo and company name on the same credential that opens the door. Because thick clamshell prox cards will not feed through a standard ID card printer, the printable card type should be named in the credential specification. Tenant cards can then be enrolled in a planned session before move-in, so new occupants arrive to doors that already recognize them.

Plan the Closeout Record Before the Ribbon Cutting

A thorough closeout package protects the owner’s credential program long after the integrator leaves. It should record the card technology, data format, facility code, the range of card numbers already issued, spare card counts, and administrator access to the panel. These details matter because one 26-bit facility code supports up to 65,535 card numbers, and the open format allows another site to share the same facility code and numbers.

Owners with several locations often assign each site its own facility code or adopt an organization-specific format such as HID’s 35-bit Corporate 1000, where card numbers are tracked to prevent duplicates.

With that record on file, reordering becomes straightforward. Partnering with a specialist like Avon Security Products, which has supplied more than 25,000 Canadian organizations, means new cards match the existing format, facility code, and number range. Every credential added later then works with the readers already installed.

Taken together, the credential format connects the readers, the panel, and every card occupants carry. Deciding it during design and documenting it at closeout gives the owner a door system that works on opening day and can grow without replacing cards that still work.

Share this post :

Facebook
Twitter
LinkedIn
Pinterest

Stay close to the industry.

CCR updates, digital magazines, events, and partner insights.

Current Issue — CCR #10

Editorial & Third-Party Content Notice: Articles, press releases, company announcements, and accompanying media (including photography, graphics, and video) published on this site may be provided by third-party contributors, PR representatives, or wire sources as cited. Authorship and original copyrights remain with their respective holders.

Commercial Construction & Renovation is a registered service provider under the Digital Millennium Copyright Act (DMCA). To submit an inquiry, copyright claim, or formal takedown request, you may view our registered agent listing and official contact details via the U.S. Copyright Office DMCA Designated Agent Directory, or contact our compliance desk directly at publisher@ccr-mag.com.

Receive the CCR 2024 Idustry Report

Get ahead of your Competitors with CCR's FREE Industry Insider's Report 2024!

Always stay two steps ahead of your Competitors. Stay informed with the latest in the Industry. 

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

This site uses cookies to ensure that you get the best user experience. By choosing “Accept” you acknowledge this and that ccr-mag.com operates under the Fair Use Act. Furthermore, Changing privacy laws now require website visitors from EEA based countries to provide consent in order to use personalized advertising or data modeling with either Google Ads & Analytics. Find out more on the Privacy Policy & Terms of Use Page and our Editorial & DMCA Notice.