Researchers Reveal Window Materials Fire Performance Insights

In a session sponsored by the Western Region of the Fenestration and Glazing Industry Alliance (FGIA), participants heard the latest research from an experimental campaign to investigate the performance of window components, particularly glazing types and frame materials, during a structure-to-structure fire spread scenario. UL Research Institutes’ Fire Safety Research Institute (FSRI) engineers Daniel Gorham and Joseph Willi presented their findings along with Gavin Horn, Research Director, in a session at the FGIA Annual Conference entitled, “How Window Materials Perform Under Fire Exposure.”

FGIA FireSafetyResearchInstitute GavinHorn KathyKrafkaHarkema DanielGorham JosephWilli

Image Courtesy of: FGIA

Findings from this work may impact decisions of homeowners and homebuilders regarding the selection and installation of window assemblies in areas prone to wildland urban interface (WUI) fire hazards. Codes, standards and guidance documents provide requirements and recommendations for resisting exposures from WUI fires. Window performance has been shown to be a key factor in a structure’s survivability during exterior fire exposures, according to the Institute. “Most of these fires start from an ember,” said Horn in his opening remarks. “They break off trees or shrubs or even other structures. If those embers find a receptive fuel bed, they can directly ignite structures.”
Horn said there is much to be learned from the aftermath of these events. “They have become all too common here on the West Coast,” he said. “We can view the chain of failure and retrace our steps. There are a lot of reasons why a structure might survive when one next to it did not.” He added that while construction plays a big role, so do factors like timing and magnitude of the wind. “We can take this information and help better prepare future homes, looking at individual components in a controlled manner.”

Building Susceptibility

Ignite mechanisms are exposure from flames and embers, explained Gorham. The magnitude and duration of that exposure is a function of fuel, distance between burning fuel and a structure or target and external factors like wind and other interventions. “Vulnerability can be mitigated by hardening structures for exposure,” he said. “The building envelope is crucial to this. A building is more than the sum of its parts: it is how those components interface with each other.” Components include the roof, eaves, siding, doors and windows.
“Doors can be resistant to embers, but we have to remember the human factor,” he said. “The best design can’t protect against the error of leaving a door open. When it comes to windows, install dual or multi-panel ones.”

Exterior Fire on Residential Windows
Willi went into the research itself, which studied structure-to-structure fire spread experiments. All consisted of a targeted façade wall with window pane assemblies and window frames made of both single materials (vinyl) and multiple materials (aluminum, fiberglass exterior, wood). “We also tested some window protections like shutters,” he added.

Window Pane Experiments
Four types of double pane window assemblies were studied: both panes annealed glass; both panes tempered glass; fire side annealed, back side tempered; and fire side tempered, back side annealed. Windows were mounted in the target wall facing the exposure. “Failure was defined as the first instance of cracking,” said Willi. “We compared heat levels at time of failure and looked at the number of total failures out of our 20 samples of all four assembly types.”

Key Takeaways

  • Window pane assemblies with annealed glass on the fire (exterior) side and tempered glass on the back (interior) side outperformed windows with the opposite configuration.
  • Window pane assemblies with both panes tempered glass performed the best of the four types considered in this study.
  • Heat transfer through windows has the potential to ignite interior combustibles even without window failure.
  • Frames and other window components should also be considered when addressing window failure from exterior fire exposure.

Window Frame Experiments

For the frame experiments, the team focused on vinyl, wood, fiberglass and aluminum frames. All windows were double pane tempered glass. They tested each frame type at four different positions in the façade, totaling 16 paired observations per frame for statistical comparison between types. “We compared the total number of occurrences, time relative to flashover and heat load,” said Willi. “Window events included back side smoke, front side fire, back side fire and sash failure.”

Share this post :

Facebook
Twitter
LinkedIn
Pinterest

Stay close to the industry.

CCR updates, digital magazines, events, and partner insights.

Current Issue — CCR #10

Editorial & Third-Party Content Notice: Articles, press releases, company announcements, and accompanying media (including photography, graphics, and video) published on this site may be provided by third-party contributors, PR representatives, or wire sources as cited. Authorship and original copyrights remain with their respective holders.

Commercial Construction & Renovation is a registered service provider under the Digital Millennium Copyright Act (DMCA). To submit an inquiry, copyright claim, or formal takedown request, you may view our registered agent listing and official contact details via the U.S. Copyright Office DMCA Designated Agent Directory, or contact our compliance desk directly at publisher@ccr-mag.com.

Receive the CCR 2024 Idustry Report

Get ahead of your Competitors with CCR's FREE Industry Insider's Report 2024!

Always stay two steps ahead of your Competitors. Stay informed with the latest in the Industry. 

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

This site uses cookies to ensure that you get the best user experience. By choosing “Accept” you acknowledge this and that ccr-mag.com operates under the Fair Use Act. Furthermore, Changing privacy laws now require website visitors from EEA based countries to provide consent in order to use personalized advertising or data modeling with either Google Ads & Analytics. Find out more on the Privacy Policy & Terms of Use Page and our Editorial & DMCA Notice.