At the Fenestration and Glazing Industry Alliance (FGIA) Virtual Summer Summit, industry leaders tackled critical technical challenges. Experts led high-impact, interactive sessions on sealant selection, the new version of the North American Fenestration Standard (NAFS) and complex window glass design, equipping professionals with actionable strategies to elevate product performance.
Learning About Sealant Compatibility

In the panel “Sealants: Compatibility and Performance for Proper Selection,” three industry experts provided their distinct points of view based upon their unique experience and expertise, including Steve Altum (Dow Performance Silicones), Lori Dahlman (Bostik) and Brandon Rhoades (H.B. Fuller).
Rhoades discussed the testing and performance of sealants, starting with the difference between a single and a dual seal within an insulating glass unit (IGU). “A single seal has one seal along the edge, sealing the air space of that insulating cavity,” he said. “Dual has a primary and a secondary sealant, with the secondary being the outermost one. The primary is to be a moisture barrier and keep gas in. The secondary is meant to provide support and strength.” He warned single seals are only suitable for non-structural glazing applications.
Dahlman focused on setting windows in their frames and testing back bedding sealants. “A back bedding sealant creates a bond between the glass and the frame,” she explained. “It protects the unit from air and water.” AAMA 800 is the only specification used for a back bedding sealant, she said, adding that, if one is using a sealant in the field that doesn’t pass the prescribed tests within, “we want to know about it so we can expand on those minimum specifications.”
Altum shared his expertise on the use and performance of structural sealants, stressing it is important to know what one is trying to achieve with the application. “What is the required design performance? What market or geographical location is a job or product being sold into?” he asked. “It’s important to talk with your sealant suppliers and walk through different scenarios. Just because a sealant is approved doesn’t mean it will give the best adhesion possible for a specific application.”