Size records storage in cubic feet before anyone picks a cabinet. NARA’s conversion is 1.5 cubic feet per letter-size file drawer and 2 cubic feet per legal-size drawer.
Retention sets the volume. Federal agencies keep financial transaction records 6 years after final payment under NARA’s General Records Schedule 1.1, so the room has to hold six years of accumulation, not one.
A “fireproof” file cabinet is only as good as its UL 72 class. Class 350 is built to protect paper; backup tapes and photographic records need Class 150.
Commercial file drawers are typically rated for 50 to 75 lb of contents each. Four full drawers in a 36-inch lateral can put roughly 55 lb per square foot on the slab before you count the steel.
Short version: cabinets get bought last and placed wherever there’s a wall. By then the floor load, the fire rating and the drawer count have already been decided by accident.
A records room is a load and fire problem before it is a furniture problem. The cabinets are the last thing in and the first thing an inspector looks at.
Document storage belongs on the fit-out drawings because the expensive questions hang off it. How many cubic feet does the room need to hold? Retention rules answer that. How much weight lands on the slab? Drawer ratings and the cabinet layout decide it. What fire rating do the contents need? That depends on whether they are paper, tape or photographs. Leave it all to move-in week and the answers come from whatever happens to fit.
The line item nobody draws
Storage usually appears on a fit-out plan as a rectangle labeled “files.” Nobody dimensions it properly, and nobody checks it against the structural notes. Then the furniture order arrives and someone discovers that the wall was planned for four vertical cabinets and the client actually needs a run of laterals.
The cabinet choice matters for the drawings because the footprints differ so much. In one commercial range of office file cabinets, the seller’s buying guide puts vertical units at about 15 inches wide and laterals at 30 to 42 inches wide, both in 2 to 5 drawer configurations, and most of the laterals listed are 22 inches deep.
Prices on the first page of that category run from $418 for a three-drawer, 15-inch-wide steel unit to $7,249 for a 44-inch-wide fireproof cabinet, which tells you where the fire rating sits in the budget. The same seller gives 50 to 75 lb of contents as a typical commercial drawer rating and notes that a 42-inch lateral needs two people to place and level.
Laterals suit shallow alcoves and corridors; verticals pack more drawers into a narrow wall. Decide which before the millwork is drawn, not after. With JLL putting the average US fit-out at $280 per square foot in its 2025 figures, as covered in CCR’s office fit-out cost guide, redrawing a wall because the cabinets don’t fit is not a cheap correction.
Volume comes from retention, not from the old office
Most teams size storage by counting the cabinets they had. That copies every bad habit of the previous floor. Better to start from what the organization is required to keep and for how long.
Federal records officers do this with a simple unit. NARA’s records inventory instructions express every series in cubic feet, using a fixed table: one letter-size file drawer holds 1.5 cubic feet, a legal-size drawer holds 2, and a standard records center carton holds 1. The same instructions ask for the annual rate of accumulation, which is the number that actually drives the room.
Retention periods turn that rate into a total. Under NARA’s General Records Schedule 1.1, federal financial transaction records are destroyed 6 years after final payment or cancellation, while routine financial management correspondence goes after 3. Private firms work to their own schedules, but the arithmetic is identical.
| Step | Worked example (illustrative) |
| Annual accumulation of a series | 20 cubic feet a year |
| Retention, plus the current year | 6 + 1 = 7 years |
| Volume to house | 140 cubic feet |
| Letter-size drawers at 1.5 cubic feet | about 94 drawers |
| Four-drawer cabinets | about 24 cabinets |
Run it once per record series. The total is what the room has to hold on the day before the oldest year can be destroyed.
That last row is the one to put on the plan. Twenty-four four-drawer verticals is a wall roughly 30 feet long, and it changes the room.
Load: drawers, floors and who signs off
Paper is heavy, and file rooms concentrate it. Take a 36-inch-wide, 22-inch-deep lateral with four drawers loaded to 75 lb each. That’s 300 lb of contents on 5.5 square feet of floor, about 55 lb per square foot before the cabinet’s own steel. Put a solid run of them against one wall and the number is worth showing to the structural engineer.
Federal tenants don’t get a choice about this. NARA’s guidance on records held in agency office space says that even a staging area inside an office must meet the storage standards in 36 CFR 1234.10 to 1234.14, and an area able to hold more than 25,000 cubic feet must be approved as a records center. Those standards require a floor load limit set by a licensed structural engineer and posted in the room, seismic bracing for shelving, and no water piping run through records storage areas unless it is guttered and inspected.
Commercial tenants aren’t bound by the federal rule. It’s still a sensible checklist for any file room, and the piping clause in particular is the kind of thing that only gets fixed at the drawing stage.
Fire rating: what the UL 72 class actually protects
“Fireproof” on a cabinet means little until you know its class. UL’s standard for fire resistance of record protection equipment, now in its 17th edition, classifies cabinets and safes by the interior temperature they hold during a fire. The class number is that temperature in degrees Fahrenheit, and each class matches a type of record.
Tape, film and disks fail at far lower temperatures than paper, which is why one cabinet can’t be rated for everything.
Class 350 protects paper. Class 150 adds magnetic tape and photographic records. Class 125 also covers flexible computer disks. Beyond the fire endurance test, the standard includes an explosion test for sudden high heat and a fire and impact test in which the unit is dropped 30 feet and checked again.
For fit-out teams, the practical point is weight. Fire-rated cabinets carry insulated walls and are much heavier than standard steel units of the same size, so ask for the unit weight and add it to the load check. Specify them for the records that genuinely need surviving copies on site, and let everything else go in standard steel.
Draw it before the slab is spoken for
Put the file room on the drawings with three numbers written next to it: the cubic feet it must hold, the posted floor load it has been checked against, and the UL class of anything rated. If any of those is blank at design review, the room is still a rectangle labeled “files,” and it will get furnished like one.