Featured Partners

apvcoatings logo

Adart

FSU Logo

Window Film Depot

Wolverine Construction

LVC Logo

new logo

Hunter logo

Commercial Locksmith Services: A Guide for Facility Managers

Locksmith work affects both legal compliance and everyday loss prevention. Facility managers can divide the scope into two parts: the code baseline, which governs how people leave a building, and the security layer, which controls who can enter. The first is mandatory. The second should reflect the site’s risks, operating needs and budget.

Start with the code baseline on doors 

Before adding hardware, verify what the building already requires. Part D2 of the National Construction Code (Volume One) sets out core egress rules. A door on a required exit or path of travel to an exit generally must be openable from the egress side without a key and by a single action. Single-action devices must be mounted within 900 to 1100 mm of finished floor level for a downward action, or 900 to 1200 mm for a pushing action.

NCC guidance also restricts deadlocks and twist-knob operation on required egress paths. Power-operated doors on egress routes must be manually openable with a force not exceeding 110 N during a malfunction or power failure. Clause numbering can change between editions, so confirm the version enforceable in your jurisdiction. The ABCB lists NCC 2022 Amendment 2 as enforceable from 29 July 2025, with an NCC 2025 preview released on 1 February 2026.

Account for fire and accessibility requirements

Fire safety and accessibility requirements sit alongside the general egress rules. Fire doors must comply with AS 1905.1 under NCC Specification C3.4. As a result, replacing hardware on a fire door should not be treated as a routine like-for-like swap. Where an area must be accessible, lever handles need a clearance of 35 to 45 mm and a shape that a person with limited grip can operate.

The order of decisions matters. Confirm code and certification requirements before choosing hardware for convenience. A reader or keypad that improves staff access is not suitable if it compromises a certified door set or prevents single-action exit. If a building surveyor or fire engineer is involved, include them in the hardware schedule review before installation.

Choose durable mechanical hardware

AS 4145.2:2008 is the Australian standard for mechanical locksets for doors and windows in buildings, with amendments issued in 2009 and 2015. Ask suppliers which performance grade each proposed lockset has been tested to. This provides a clearer basis for comparing quotes than appearance or finish alone.

Durability problems often begin around the lock itself, including sagging hinges, poorly adjusted closers, misaligned latches and strike plates fixed to unreinforced frames. Include these items in routine inspections. A quarterly check of high-traffic doors, including latch engagement, alignment and closer speed, can identify developing faults before they lead to an after-hours callout.

Treat key control as a process

Restricted key systems limit who can duplicate a key, while master keying provides different levels of access for cleaners, contractors, staff and managers. Neither system works well without clear administration. Maintain an auditable key register, rekey or reissue credentials after a tenancy change or significant staff turnover, and review the register on a fixed schedule rather than only after an incident.

Plan electronic access control carefully

Card readers, mobile credentials and electrified hardware address two limitations of mechanical keys: they allow prompt credential revocation and create an event log. They also introduce new failure modes. Specify how every controlled door will behave during a power failure and fire alarm. Confirm battery backup for controllers and locking devices and position readers and release devices consistently with applicable egress requirements.

If the fire detection system releases controlled doors, document and test the interface rather than assuming it will work. Decide how long access logs will be retained, who may review them and how they will be protected. Logs are useful during an investigation only if the relevant records still exist. Start with a small pilot, confirm door behaviour under normal and emergency conditions, then expand the system. For Fremantle-area project scoping, Locksmith Fremantle can be considered alongside other qualified local providers.

Check licensing, credentials and privacy

Security licensing is state-based, so do not assume one national rule applies. In New South Wales, the Class 2C licence issued through the Security Licensing and Enforcement Directorate authorises selling, installing, maintaining, repairing and advising on security equipment, including locksmith work within that subclass. In Western Australia, a Class 1 Security Installer licence covering safes, vaults and locks requires the applicant to be a trade-qualified locksmith.

If the project includes cameras, address privacy during planning. The Office of the Australian Information Commissioner notes that workplace surveillance and monitoring are primarily governed by state and territory laws. The federal Privacy Act does not specifically regulate workplace surveillance. Check the applicable state legislation, workplace policies and staff notification obligations before installation.

Set clear hiring and handover requirements

Ask prospective contractors for four items: a compliance plan referencing the applicable NCC provisions, a door-by-door hardware schedule, a draft key-control policy and a process for handling staff or tenancy changes. A review of commercial security upgrades can help identify scope gaps before quotes are compared. For sites in the Fremantle area, Gronbek Security is one MLAA member that scopes restricted key, access control and CCTV projects under Western Australian licensing rules. Its local service can be considered alongside other qualified local providers.

A simple schedule can keep the work manageable. In the first 30 days, correct egress issues and document every required exit. By 60 days, update the key register and move higher-risk areas to restricted keys where appropriate. By 90 days, pilot electronic access control on a small group of doors and document the operating, emergency and credential-management procedures.

The practical takeaway

Compliance and security are related but separate goals. Confusing them can lead to unsuitable hardware and costly rework. Verify the egress baseline, select hardware against relevant standards, manage keys through a documented process and add electronic controls only after the doors operate reliably. Whether a facility engages Gronbek Security or another appropriately licensed provider, the same scoping, compliance and handover questions should apply.

 

Share this post :

Facebook
Twitter
LinkedIn
Pinterest

Stay close to the industry.

CCR updates, digital magazines, events, and partner insights.

Current Issue — CCR #10

Editorial & Third-Party Content Notice: Articles, press releases, company announcements, and accompanying media (including photography, graphics, and video) published on this site may be provided by third-party contributors, PR representatives, or wire sources as cited. Authorship and original copyrights remain with their respective holders.

Commercial Construction & Renovation is a registered service provider under the Digital Millennium Copyright Act (DMCA). To submit an inquiry, copyright claim, or formal takedown request, you may view our registered agent listing and official contact details via the U.S. Copyright Office DMCA Designated Agent Directory, or contact our compliance desk directly at publisher@ccr-mag.com.

Receive the CCR 2024 Idustry Report

Get ahead of your Competitors with CCR's FREE Industry Insider's Report 2024!

Always stay two steps ahead of your Competitors. Stay informed with the latest in the Industry. 

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

This site uses cookies to ensure that you get the best user experience. By choosing “Accept” you acknowledge this and that ccr-mag.com operates under the Fair Use Act. Furthermore, Changing privacy laws now require website visitors from EEA based countries to provide consent in order to use personalized advertising or data modeling with either Google Ads & Analytics. Find out more on the Privacy Policy & Terms of Use Page and our Editorial & DMCA Notice.